We are an ISO-certified company. We are looking for a sales channel partner for our products in your country.
Categories
SeraFlon PTFE Cartridge Double Layer Sterilizing Grade 0.2 Micron PTFE Membrane Filter Cartridge SeraFlon Hydrophobic PTFE Sterilizing Grade 0.2um filter.cartridges are highly retentive hydrophobic membrane designed for critical liquid and gas sterilization. Hydrophobic PTFE filter medium provides exceptionally high air flow rates at low differential pressures Naturally Hydrophobic Membrane also provides high assurance of filter integrity and long life, during high temperature venting application and during repeated steaming. The PTFE membrane with specially designed high temperature construction provides excellent chemical compatibility and superior flow per unit area of steam-in-place and hot gas application. Validated PTFE Membrane All Cartridges are 100% integrity tested prior to release –(Click here for Validation Guide) PTFE Filters provide microorganism retention based on following validation method • Brevundimonas (Pseudomonas) diminuta liquid bacteria challenge : Complete retention of ≥ 107 organism of (ATCC-19146) Brevundimonas diminuta /cm² of effective filtration area in accordance with the current HIMA challenge methodology (ASTM F838-05) • Aerosol Bacteriophage challenge (Gas) : Validated by aerosol bacterial (Staphylococcus aureus ) and Viral (ø x174 Bacteriophage) challenge Test INTEGRITY TESTING HYDROPHOBIC FILTERS The hydrophobic membranes find application as air filters, generally as vent filters. These protect the contents of the tanks or other containers against contamination by the air that enters or leaves them as occasioned by the addition or withdrawal of their stored liquids. The concern is with the possibility of water finding lodgment in the membranes as a result of splashing, foaming, or even by the condensation of water vapor. Liquid water would possibly impede air passage, conceivably leading to tank collapse upon outpumping; moreover, water would encourage microbial growth. Contamination therewith is strongly to be avoided. The prescription against such an occurrence is to deny the presence of moisture. This can be done for hydrophilic filters using electrically heated or steam-jacketed filter housings. The temperature is raised above the dew point of the ambient air. Usually, steam at 1/3 bar (5 psi) pressure is enough. Unfortunately, the long term passage of air through such heated arrangements will cause the oxidative degradation of certain filter cartridge components, such as polypropylene, and may also oxidatively degrade the microporous membrane itself, depending upon its composition. Fluorinated polymers are relatively immune to oxidative alteration; PTFE extremely so, PVDF somewhat less so. That is why these polymers are so widely used in air filtration contexts. The greater hydrophobicity of PTFE offers substantial advantages Water Intrusion Test The water intrusion test measures the decay rate of a pressure level imposed upon a hydrophobic filter enveloped by water. By means of an automated integrity tester, a particular decay level is identified as the point at which water enters the largest pores of the filter. The water intrusion test depends upon and measures the hydrophobicity of the filter. Only the experimentally demonstrated correlation of its values with the entrance of water into the hydrophobic pore structure establishes it as an integrity test. But the basic measurement of filter hydrophobicity is itself an inherent requirement in its pertinence to air filter reuse. Consider an integral air filter that contains hydrophilic accretions or deposits upon its surface. Their presence may encourage microbial growth and, ultimately, organism penetration. Solely ensuring air filter integrity, however essential, is not enough in air filter usage. The filter’s full hydrophobicity must also be assessed to ensure freedom from compromising hydrophilic impurities. Advantages and Disadvantages of Water Intrusion Testing The water intrusion test offers several advantages. For example, 1. The test is highly sensitive because its test pressures are in the range of the WPP of 0.45 mm rated filters. 2. Contaminants such as solvent mixtures ( IPA & Water) are avoided. 3. In addition to the integrity, the validated hydrophobicity is tested, i.e., any contaminants on the membrane can be discovered. 4. The test can be performed in place, after steam sterilization. 5. Test times are greatly reduced, because contaminants do not have to be flushed off and in-place testing is not necessary. The specifications defined by the filter manufacturers have to be observed to achieve reliable test results. In most cases the test is performed with automated test machines. This may be considered a disadvantage because of capital costs incurred. Nevertheless, automated test machines are usefully versatile and are also commonly used to perform other integrity tests such as the diffusive airflow and bubble point tests. Long-Term Air Filter Applications As previously stated, in the usual air filtration or vent filter applications, the filter is so little exhausted by the depositions it collects that its reuse is compelled for economic reasons; hence the need periodically to repeat its integrity verification before and after each individual use, ideally without removing it from its installation. The filter may remain integral, but if it collects, as it well may, deposits of hydrophilic matter, then as localized and limited as these may be, they can serve as loci for organism growth and penetration, defeating the very purpose intended by the use of a hydrophobic filter. If the intention of the integrity test in air filtration applications is solely to assess filter integrity, then the water intrusion test may, on occasion, mislead and be responsible for the discard of integral filters. If, however, the purpose of examining the filter is to gauge its suitability as a longer-term air filter, as in fermenter operations for example, then the water intrusion test is sovereign for the purpose because it simultaneously measures the integrity and the hydrophobicity of the subject filter. Both of these properties are required in a filter dedicated to longer-term air filtration applications. Natural Hydrophobicity Free air flow with little resistance requires that the filter does not wet with water or moisture. In order to prevent pore blockage, an extremely hydrophobic PTFE membrane is used which prevents wetting with water or moisture. This Inherently Hydrophobic cartridge with an absolute removal rating of 0.2µm in liquids and 0.003µm in gas & air are highly recommended for sterile filtration of gas & air in pharmaceutical, biological liquids and fermentation industries. For documentation accuracy each cartridge includes a Certificate of Quality, summarizing lot release and audit testing data. For tracing purpose, each Cartridge is labeled with pore size, lot no., Serial No. and Specific product code. No adhesives, binders or surfactants are used in manufacturing process. Each cartridge is rinsed with high-purity water to reduce extractables and downtime and double bag packed. Industrial Application • Sterilizing Grade Vent Filter for Tank Venting and Product. • Compressed air filtration (Sterile Air) • Sterilizing filtration of fermentation inlet and exhaust air • Bioreactor (Fermentor) inlet and outlet gas and air filtration • Sterile air filtration on blow, fill and sealmachines • Sterile venting of Process Vessels and Carboys • Autoclave vacuum break line • Sterile venting of lyophilisers • Sterile process gas filtration • Sterilize alcohol stream Features & Benefits • High Void Volumes • High air flow at low pressure drops • High steam cycle lifetimes and long service Benefits • Highest Hydrophobicity of membrane • Fully integrity testable by Water Intrusion, Bubble Point or Diffusion Flow test that ensures integrity and reliability. • Validated by bacterial retention test B.diminuta (ATCC-19146) & Aerosol Bacteriophage challenge • USFDA CFR Title 21 materials of construction, USP Class VI Biological Safety Test, Validation Guide and Drug Master File listing eases validation and regulatory submission • Capsule filters are available in both gamma compatible and sterile formats which Eliminate cleaning and cleaning validation step associated with stainless steel housings for maximal ease-of-use. Technical Specification Nominal Dimension Operating Parameter Sterilization & Autoclaving The filters can be sterilized by autoclaving for up to 200 cycles at 275°F/126°C. The filters can also be sterilized by steam-in-place procedure up to 200 cycles at 287.6°F/142°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or common chemicals that are compatible with filter components. Retention For 0.2um (0.003um in Gas) Liquid: Complete retention of > 107 organism/cm² of Brevundimonas (Pseudomonas) diminuta /cm² of effective filtration area in accordance with the current HIMA challenge methodology (ASTM F838-05)Gas: Validated by aerosol bacterial (Staphylococcus aureus ) and Viral (ø x174 Bacteriophage) challenge Test Flow Rate vs. Differential Pressure Ordering Information Integrity tested All SeraFlon cartridges are 100% integrity tested—Validation Guide available upon request. Product validation guide available on request. All SeraFlon cartridges are manufactured under strict control with batch number identification, giving full traceability on all components.
Sterilizing Grade 0.2 Micron PTFE Membrane Filter Cartridge
SeraFlon Hydrophobic PTFE Sterilizing Grade 0.2um filter.cartridges are highly retentive hydrophobic membrane designed for critical liquid and gas sterilization. Hydrophobic PTFE filter medium provides exceptionally high air flow rates at low differential pressures Naturally Hydrophobic Membrane also provides high assurance of filter integrity and long life, during high temperature venting application and during repeated steaming. The PTFE membrane with specially designed high temperature construction provides excellent chemical compatibility and superior flow per unit area of steam-in-place and hot gas application.
All Cartridges are 100% integrity tested prior to release –(Click here for Validation Guide) PTFE Filters provide microorganism retention based on following validation method • Brevundimonas (Pseudomonas) diminuta liquid bacteria challenge : Complete retention of ≥ 107 organism of (ATCC-19146) Brevundimonas diminuta /cm² of effective filtration area in accordance with the current HIMA challenge methodology (ASTM F838-05) • Aerosol Bacteriophage challenge (Gas) : Validated by aerosol bacterial (Staphylococcus aureus ) and Viral (ø x174 Bacteriophage) challenge Test
The hydrophobic membranes find application as air filters, generally as vent filters. These protect the contents of the tanks or other containers against contamination by the air that enters or leaves them as occasioned by the addition or withdrawal of their stored liquids. The concern is with the possibility of water finding lodgment in the membranes as a result of splashing, foaming, or even by the condensation of water vapor. Liquid water would possibly impede air passage, conceivably leading to tank collapse upon outpumping; moreover, water would encourage microbial growth. Contamination therewith is strongly to be avoided. The prescription against such an occurrence is to deny the presence of moisture. This can be done for hydrophilic filters using electrically heated or steam-jacketed filter housings. The temperature is raised above the dew point of the ambient air. Usually, steam at 1/3 bar (5 psi) pressure is enough. Unfortunately, the long term passage of air through such heated arrangements will cause the oxidative degradation of certain filter cartridge components, such as polypropylene, and may also oxidatively degrade the microporous membrane itself, depending upon its composition. Fluorinated polymers are relatively immune to oxidative alteration; PTFE extremely so, PVDF somewhat less so. That is why these polymers are so widely used in air filtration contexts. The greater hydrophobicity of PTFE offers substantial advantages
The water intrusion test measures the decay rate of a pressure level imposed upon a hydrophobic filter enveloped by water. By means of an automated integrity tester, a particular decay level is identified as the point at which water enters the largest pores of the filter. The water intrusion test depends upon and measures the hydrophobicity of the filter. Only the experimentally demonstrated correlation of its values with the entrance of water into the hydrophobic pore structure establishes it as an integrity test. But the basic measurement of filter hydrophobicity is itself an inherent requirement in its pertinence to air filter reuse. Consider an integral air filter that contains hydrophilic accretions or deposits upon its surface. Their presence may encourage microbial growth and, ultimately, organism penetration. Solely ensuring air filter integrity, however essential, is not enough in air filter usage. The filter’s full hydrophobicity must also be assessed to ensure freedom from compromising hydrophilic impurities.
The water intrusion test offers several advantages. For example, 1. The test is highly sensitive because its test pressures are in the range of the WPP of 0.45 mm rated filters. 2. Contaminants such as solvent mixtures ( IPA & Water) are avoided. 3. In addition to the integrity, the validated hydrophobicity is tested, i.e., any contaminants on the membrane can be discovered. 4. The test can be performed in place, after steam sterilization. 5. Test times are greatly reduced, because contaminants do not have to be flushed off and in-place testing is not necessary. The specifications defined by the filter manufacturers have to be observed to achieve reliable test results. In most cases the test is performed with automated test machines. This may be considered a disadvantage because of capital costs incurred. Nevertheless, automated test machines are usefully versatile and are also commonly used to perform other integrity tests such as the diffusive airflow and bubble point tests.
As previously stated, in the usual air filtration or vent filter applications, the filter is so little exhausted by the depositions it collects that its reuse is compelled for economic reasons; hence the need periodically to repeat its integrity verification before and after each individual use, ideally without removing it from its installation. The filter may remain integral, but if it collects, as it well may, deposits of hydrophilic matter, then as localized and limited as these may be, they can serve as loci for organism growth and penetration, defeating the very purpose intended by the use of a hydrophobic filter. If the intention of the integrity test in air filtration applications is solely to assess filter integrity, then the water intrusion test may, on occasion, mislead and be responsible for the discard of integral filters. If, however, the purpose of examining the filter is to gauge its suitability as a longer-term air filter, as in fermenter operations for example, then the water intrusion test is sovereign for the purpose because it simultaneously measures the integrity and the hydrophobicity of the subject filter. Both of these properties are required in a filter dedicated to longer-term air filtration applications.
Free air flow with little resistance requires that the filter does not wet with water or moisture. In order to prevent pore blockage, an extremely hydrophobic PTFE membrane is used which prevents wetting with water or moisture. This Inherently Hydrophobic cartridge with an absolute removal rating of 0.2µm in liquids and 0.003µm in gas & air are highly recommended for sterile filtration of gas & air in pharmaceutical, biological liquids and fermentation industries. For documentation accuracy each cartridge includes a Certificate of Quality, summarizing lot release and audit testing data. For tracing purpose, each Cartridge is labeled with pore size, lot no., Serial No. and Specific product code. No adhesives, binders or surfactants are used in manufacturing process. Each cartridge is rinsed with high-purity water to reduce extractables and downtime and double bag packed.
• Sterilizing Grade Vent Filter for Tank Venting and Product. • Compressed air filtration (Sterile Air) • Sterilizing filtration of fermentation inlet and exhaust air • Bioreactor (Fermentor) inlet and outlet gas and air filtration • Sterile air filtration on blow, fill and sealmachines • Sterile venting of Process Vessels and Carboys • Autoclave vacuum break line • Sterile venting of lyophilisers • Sterile process gas filtration • Sterilize alcohol stream
• High Void Volumes • High air flow at low pressure drops • High steam cycle lifetimes and long service Benefits • Highest Hydrophobicity of membrane • Fully integrity testable by Water Intrusion, Bubble Point or Diffusion Flow test that ensures integrity and reliability. • Validated by bacterial retention test B.diminuta (ATCC-19146) & Aerosol Bacteriophage challenge • USFDA CFR Title 21 materials of construction, USP Class VI Biological Safety Test, Validation Guide and Drug Master File listing eases validation and regulatory submission • Capsule filters are available in both gamma compatible and sterile formats which Eliminate cleaning and cleaning validation step associated with stainless steel housings for maximal ease-of-use.
The filters can be sterilized by autoclaving for up to 200 cycles at 275°F/126°C. The filters can also be sterilized by steam-in-place procedure up to 200 cycles at 287.6°F/142°C for 30 minutes at less than 0.3 bar differential pressure. The filters can also sanitized by hot water or common chemicals that are compatible with filter components.
For 0.2um (0.003um in Gas) Liquid: Complete retention of > 107 organism/cm² of Brevundimonas (Pseudomonas) diminuta /cm² of effective filtration area in accordance with the current HIMA challenge methodology (ASTM F838-05)Gas: Validated by aerosol bacterial (Staphylococcus aureus ) and Viral (ø x174 Bacteriophage) challenge Test
All SeraFlon cartridges are 100% integrity tested—Validation Guide available upon request. Product validation guide available on request. All SeraFlon cartridges are manufactured under strict control with batch number identification, giving full traceability on all components.